The Koldlok Extended unit is particularly useful when sealing large cutouts that adjoin walls where large conduit or power cable bundles extend through the raised-floor.
The Koldlok Extended unit is currently available in our 24″ length (23 15/16 actual) with a brush size of either six or three inches. The overall size for the three inch unit is: 23 15/16 x 6 x 1, sealing an opening of up to 23 15/16″ x 3″. The overall size for the six inch unit is: 23 15/16 x 9 x 1, sealing an opening of up to 23 15/16″ x 6″.
All Koldlok Extended units provide a secure fit to raised-floor tile utilizing either our unique adhesive gaskets or by actually screwing the unit down. Our kit provides all the materials you need to quickly and efficiently seal cable openings. As with our standard Koldlok products, these also dissipate static charge buildup to prevent ESD and come with a full one year warranty.
All KoldLok products provide the following benefits:
Allow easy pass-through of power plug connectors and large cable bundles of up to 4 x 8
Large usable opening combined with very effective sealing allows Koldlok to fulfill most cable cutout requirements
Increase under-floor static pressure
Make Hot Aisle/Cold Aisle cooling concepts feasible above 50 watts/sf
Reduce cooling unit incapacity
Learn more about KoldLok Raised Floor Grommet products:
To learn more about PTS consulting services to support data center, computer room, and server room design, build, management, and maintenance, contact us or visit:
KoldLok Integral The Koldlok Integral is an airflow management device designed to seal cable openings in new raised-floor systems prior to the installation of communication or power cabling.
Special Features
The Split Integral Grommets allow tiles to be moved without capturing cables
The Grommets integrate with the raised-floor static dissipation system 32 square inch usable cabling area accommodates a variety of cabling requirements, including 100 amp power connectors
The Grommets satisfy NFPA 75 Section 5-4.4 requirement by self-dressing the raw metal edges of raised-floor tile cable cutouts
The Grommets contain no loose or partially fastened parts, which can become separated or fall through the raised floor.
Compliant with the directive that restricts the use of certain hazardous substances in electrical and electronic equipment (RoHS)
All KoldLok products provide the following benefits:
Allow easy pass-through of power plug connectors and large cable bundles of up to 4 x 8
Large usable opening combined with very effective sealing allows Koldlok to fulfill most cable cutout requirements
Increase under-floor static pressure
Make Hot Aisle/Cold Aisle cooling concepts feasible above 50 watts/sf
Reduce cooling unit incapacity
Learn more about KoldLok Raised Floor Grommet products:
To learn more about PTS consulting services to support data center, computer room, and server room design, build, management, and maintenance, contact us or visit:
The Koldlok Round is the premium choice for your facility. Its revolutionary sealing technology greatly reduces costly bypass airflow, increasing useable cooling unit capacity, and ensuring maximized efficiency from HVAC equipment.
Special Features:
The Split feature of the KoldLok Round 4″ allows product installation or removal without disturbing cables.
The Grommets contain no loose or partially fastened parts, which can become separated or fall through the raised floor.
The Grommets are impact resistant and durable.
HBT Membrane Layer
The Grommets satisfy NFPA 75 Section 5-4.4 requirement by self-dressing the raw metal edges of raised floor tile cable cutouts.
KoldLok products are compliant with directive 2002/95/EC of the European Parliament and the Council on the Restriction of the Use of Certain Hazardous Substances in Electrical and Electric Equipment (RoHS).
Membrane support structure.
Tapered joining structure.
Learn more about KoldLok Raised Floor Grommet products:
To learn more about PTS consulting services to support data center, computer room, and server room design, build, management, and maintenance, contact us or visit:
By utilizing our new Koldlok Surface Mount L or XL extensions, larger cable openings can be sealed while maintaining all of the benefits of our standard Koldlok products.
The Surface Mount L will seal a cable opening up to 9 x 10 extending the capacity of our current Surface Mount coverage by two inches. The Surface Mount XL nearly doubles the normal sealing capacity of our standard Surface Mount to seal an opening up to 10″ x 13″. Utilizing either of these solutions allows data center managers to accommodate odd shaped cable openings, previously outside the range of our Koldlok products.
All Koldlok Surface Mount L & XL’s provide a secure fit to raised-floor tile utilizing either our unique adhesive gaskets or by actually screwing the unit down. Our kit provides all the materials you need to quickly and efficiently seal cable openings. As with our standard Koldlok products, these also dissipate static charge buildup to prevent ESD and come with a full one year warranty.
All KoldLok products provide the following benefits:
Allow larger cable openings to be sealed with the same effectiveness as our standard Koldlok Surface Mount unit
Enable precision delivery of cooling where its needed
Increased perforated tile and grate cooling delivery
Increase under-floor static pressure
Make Hot Aisle/Cold Aisle cooling concepts feasible above 50 watts/sf
Reduce cooling unit incapacity
Learn more about KoldLok Raised Floor Grommet products:
To learn more about PTS consulting services to support data center, computer room, and server room design, build, management, and maintenance, contact us or visit:
The Koldlok Surface Mount is designed for installation in active raised floor data centers to seal cable openings without affecting operations. Like the original Integral, the Surface Mount seals cable cutouts to prevent cooling air from bypassing heat-generating computer equipment racks.
Engineered as a split device, the Surface Mount comes apart to facilitate placement around cable bundles. Installation on floor tiles is accomplished through special adhesives, eliminating the need for tools and drilling.
Features
Installs in active data centers without affecting operations.
Installs easily around existing cable cutouts and can be separated to facilitate recalling.
Enables precision-cooled air delivery to computer equipment air intakes, especially to the top of the racks.
Allows easy pass-through of power plug connectors and large cable bundles of up to 4 x 8.
No training, tools, or quality control is required to assure resealing after cables have been installed or removed.
Increases static pressure and airflow through perforated tiles or grates.
Reduces cooling unit incapacity.
Specifications
Grommet housing is made of heavy-duty, high impact resistant, molded polypropylene.
Double layers of opposing conductive filaments seal around cables with up to 100% effectiveness.
Overall size: 11″ x 8 1/4″ x 1 1/8″
Usable cable opening size: 8 1/4″ x 4″
Total cable opening size 8 1/4″ x 5″
Learn more about KoldLok Raised Floor Grommet products:
To learn more about PTS consulting services to support data center, computer room, and server room design, build, management, and maintenance, contact us or visit:
The Koldlok Wave Split Integral Raised Floor Grommet is designed to seal openings in new or existing raised floor cutouts prior to the installation of communications, power, or cabling. It is beneficial in its ability to allow greater IT density and sealing against by-pass airflow.
Special Features:
Sealing Effectiveness – New, patent-pending wave shaped thermoplastic elastomer offers the best sealing against bypass air flow, unsurpassed by any brush grommet on the market.
Usable Cable Area – Offers 45.5 sq inches of usable cable area, over two and a half times that of a leading brush competitor.
Maintenance Free – Wave shaped material seals around cables with no additional maintenance or monitoring required.
Configuration – Split design allows edge-cut tiles to be removed without capturing cables.
Fire Resistant – Thermoplastic elastomer material is rated UL94 HB.
Longevity – Durable, impact-resistant ABS frame.
Safety Cover – An optional cover is available to ensure greater safety before rack and cable installation.
For more details, please contact us or click on the link below:
To learn more about PTS consulting services to support data center, computer room, and server room design, build, management, and maintenance, contact us or visit:
Seal Cable Openings & Eliminate Data Center Hot Spots Triton has developed a specialized and patented* line of products designed to meet the needs of high-availability data centers. The KoldLok line of products specifically addresses the issue of bypass airflow and its detrimental effect on data center cooling. Based on measurements at multiple data centers, unsealed cable openings allow 50% to 80% of conditioned cold air to escape prematurely. Sealing raised-floor tile cutouts is an essential component of data-center reliability and availability. KoldLok products provide solutions for newly built centers as well as retrofitting older facilities.
The Integral KoldLok is designed specifically for installation in new data center raised-floor cable cutouts before equipment arrives or in existing sites during equipment moves. The KoldLok Surface Mount and KoldLok Split Integral units can be installed in live data centers without affecting operations for those situations where existing equipment cant be moved or unplugged. The KoldLok Extended Brush and the KoldLok Surface L & XL units are intended to fill holes in raised flooring that are non-standard and require a more flexible solution.
All KoldLok products provide the following benefits:
Precision delivery of cooling where it is needed
Increased perforated tile and grate cooling delivery
Increased under-floor static pressure
Make Cold Aisle/Hot Aisle cooling concepts feasible above 50 watts/ft2
The KoldLok Integral raised-floor grommet is designed for installation in new or existing raised-floor tiles prior to the installation of racks or cabinets containing computer and communication equipment.
By utilizing our new KoldLok Surface Mount L or XL extensions, larger cable openings can be sealed while maintaining all of the benefits of our standard KoldLok products.
The KoldLok Extended unit is particularly useful when sealing large cutouts that adjoin walls where large conduit or power cable bundles extend through the raised-floor.
The KoldLok Round is the premium choice for your facility. Its revolutionary sealing technology greatly reduces costly bypass airflow, increasing useable cooling unit capacity, and ensuring maximized efficiency from HVAC equipment.
The KoldLok Wave Split Integral Raised Floor Grommet is designed to seal openings in new or existing raised floor cutouts prior to the installation of communications, power, or cabling. It is beneficial in its ability to allow greater IT density and sealing against by-pass airflow.
To learn more about PTS consulting services to support data center, computer room, and server room design, build, management, and maintenance, contact us or visit: