UPS for Computers and Peripherals
- Back-UPS ES (350VA – 750VA)
Best Value Battery Backup & Protection for Home Computers.Download Brochures:
Back-UPS CS (350VA – 650VA)Best Value Battery Backup & Protection for Business Computers.
- Back-UPS RS (500VA – 1500VA)High Performance Battery Backup & Protection for Business Computers.Download Brochures:
- Back-UPS HSSuperior power management and protection for dataline panel box and home networking equipment.
Additional UPS solutions from APC:
PTS Uninterruptible Power Supply (UPS) Services
UPS for Data Center, Computer Room, and Facility 3-Phase
- Smart-UPS VT (10 to 40kVA (30kVA in 208V))Compact 3-phase power protection with scalable runtime for small data centers and other business critical applications.
Download Brochure
- Symmetra PX (10 to 500 kVA/kW)Right-sized, modular, scalable 3-phase power protection for any size data center or high density power zone.
Download Brochure
- Symmetra MW (400kW to 1.6MW)
Modular, scalable, 3-phase power protection with industry leading efficiency and robust performance for large data centers and facilities.
Download Brochure
- MGE EPS 6000 (300 kVA to 375 kVA)Performance 3 phase power protection with high adaptability to meet the unique requirements of medium to large data centers, buildings and mission critical environments.
Download Brochure
- MGE EPS 7000 (300 kVA to 500 kVA)Performance 3 phase power protection with high adaptability to meet the unique requirements of medium to large data centers, buildings and mission critical environments.
Download Brochure
- MGE EPS 8000 (555 kVA to 1100 kVA)Performance 3 phase power protection with high active power density and adaptability to meet the unique requirements of very large data centers, buildings and mission critical environments.
Download Brochure
- MGE Galaxy 5000 (20 – 120kVA (400V), 50 – 130kVA (480V))
Flexible 3 phase power protection designed to meet a wide range of requirements from data centers to industrial and facilities applications.
Download Brochure
- MGE Galaxy 3500 ((10 – 30 kVA (208V), 10 – 40 kVA (400V)))Performance 3 phase power protection with excellent efficiency and optimized footprint for commercial facilities and industrial environments.
Download Brochure
- MGE Galaxy 4000 (40 – 75kVA)Flexible 3 phase power protection designed to meet a wide range of requirements from data centers to industrial and facilities applications.
Download Brochure
- MGE Galaxy PW (150 – 225kVA)Flexible 3 phase power protection designed to meet a wide range of requirements from data centers to industrial and facilities applications.
Download Brochure
Additional UPS solutions from APC:
PTS Uninterruptible Power Supply (UPS) Services
To learn more about PTS consulting services to support Air Conditioning Equipment & Systems deployments and support, contact us or visit:
InfraStruxure InRow RC Chilled Water Data Center Cooling Solutions provide high capacity precision air conditioning to maximize cooling for high efficiency operation. The solution is an excellent choice for medium to large data centers.
The InRow RC is a chilled water modular air conditioning unit that is available in either a half-rack (ACRC100 series) or a full-rack (ACRC500 series) model. This user’s guide describes the features of the ACRC100-series cooling units. The ACRC100-series models are the widths of a standard enclosure, and can be placed in a data-center row. The InRow RC provides full management capabilities over a network using Telnet, Secure Shell (SSH), HTTP,HTTPS, FTP, Secure Copy (SCP), Modbus, and SNMP.
- Hot swappable fans: Allows system to remain operational if a fan replacement is required.
- Washable filters: Easy to maintain, cleanable, deep loading mesh filter removes particles from the return air stream.
Features & Benefits
FEATURES |
BENEFITS |
Availability |
Predictable cooling |
Placing the unit in the row of racks moves the source of cooling closer to the heat load. This eliminates air mixing and provides a predictable cooling architecture. |
Dual A-B Power Inputs |
Draws power from the UPS for power protection with dual feeds for redundancy. |
Rack inlet control |
Rack inlet control guarantees inlet temperature to IT equipment. |
Top and bottom chilled water connections |
Allows chilled water to be connected from the top, if routing from overhead, or bottom, if on a raised floor. |
Active response controls |
Monitors and actively adjusts cooling capacity to ensure proper server inlet temperatures. Through the microprocessor controller, visibility into the operation and health of the unit is provided. |
Total Cost of Ownership |
Variable speed fans |
Variable speed fans reduce energy consumption during off-peak cooling periods. |
In-Row architecture |
Captures hot exhaust air directly from the IT equipment, thereby increasing the unit’s sensible cooling capacity over traditional cooling architectures. |
Agility |
Modular design |
Modular design provides scalable solutions to add cooling as demand increases. |
Scalable densities |
Allows for higher cooling to be achieved by integrating the Hot Aisle Containment System with row-based architecture. |
Casters |
Provides flexibility to move the unit to wherever cooling is required. |
Serviceability |
Easy service access |
Allows for all serviceable components to be replaced / maintained by easily accessible panels/doors. |
Manageability |
Microprocessor controller |
Provides proactive control and real-time monitoring via a four line, eighty character, alphanumeric display. |
Building Management System Integration |
Send alarms and data points allowing you to manage critical building infrastructure from a single system. |
Real-Time Capacity Monitoring |
Real-time display of current and available cooling. |
To learn more about PTS consulting services to support Air Conditioning Equipment & Systems deployments and support, contact us or visit: