APC UPS Networks and Servers

btn_contact

UPS for Networks and Servers

  • ups_05Smart-UPS (Entry level 420-1500VA, Standard 750-5000VA, Extended Run 750-3000VA)Intelligent and efficient network power protection from entry level to scalable runtime. Ideal for servers, point-of-sale, routers, switches, hubs and other network devices.Download Brochures:
  • Smart-UPS On-Line (1-20kVA Rack/Tower Convertible)High density, double-conversion on-line power protection with scalable runtime.Download Brochure
  • Symmetra (2-16kVA N+1 Redundant Rack or Tower)Highly available, redundant and scalable double-conversion on-line power protection.Download Brochure

APC Uniflair Room Chilled Water Data Center Cooling Solution

btn_contact

APC-Uniflair-Room-Chilled-Water-Cooling-SolutionUniflair Chilled Water (CW) products offer flexible cooling solutions perfect for racked and non-racked IT loads. The product line meets the diverse requirements of the data center environment to efficiently provide cooling at the room level. Uniflair CW offers a fully adaptable, assemble to order, product line that provides variable fan technology and intelligent control for a more efficient solution.

 Airflow Configurations
(Click image to view full-size)
(Click image to view full-size)
 Features & Benefits
FEATURES BENEFITS
Availability
Direct drive motors Stress on bearings is nearly eliminated, increasing useful life. Allows integral fan/motor assembly to be factory balanced, which lowers vibration and expedites startup.
Steam humidifier Humidity is managed through a self-contained steam canister humidifier for maximum efficiency and ease of maintenance. The pure-steam canister maintains consistent capacity output, and requires very little scheduled maintenance.
Total Cost of Ownership
Variable speed fans Variable speed fans reduce energy consumption during off-peak cooling periods.
Electric Reheat Prevents overcooling during dehumidification.
Serviceability
Front service access The system has full service, front access for routine servicing of components. Front access also narrows the footprint of the system making it possible for units to be placed side by side.
Manageability
Network interface Provides management by connecting the device directly to the network with a dedicated IP address, avoiding the need for a proxy such as a server. Management is available via Web browser, Telnet or SSH. Notification features inform you of problems as they occur.

 

APC UPS Computers and Peripherals

btn_contact
UPS for Computers and Peripherals

APC UPS for Data Center, Computer Room, and Facility 3-Phase

btn_contact

UPS for Data Center, Computer Room, and Facility 3-Phase

  • Smart-UPS VT (10 to 40kVA (30kVA in 208V))Compact 3-phase power protection with scalable runtime for small data centers and other business critical applications.

Download Brochure

  • Symmetra PX (10 to 500 kVA/kW)Right-sized, modular, scalable 3-phase power protection for any size data center or high density power zone.

Download Brochure

  • Symmetra MW (400kW to 1.6MW)ups_03Modular, scalable, 3-phase power protection with industry leading efficiency and robust performance for large data centers and facilities.

Download Brochure

  • MGE EPS 6000 (300 kVA to 375 kVA)Performance 3 phase power protection with high adaptability to meet the unique requirements of medium to large data centers, buildings and mission critical environments.

Download Brochure

  • MGE EPS 7000 (300 kVA to 500 kVA)Performance 3 phase power protection with high adaptability to meet the unique requirements of medium to large data centers, buildings and mission critical environments.

Download Brochure

  • MGE EPS 8000 (555 kVA to 1100 kVA)Performance 3 phase power protection with high active power density and adaptability to meet the unique requirements of very large data centers, buildings and mission critical environments.

Download Brochure

  • MGE Galaxy 5000 (20 – 120kVA (400V), 50 – 130kVA (480V))ups_04Flexible 3 phase power protection designed to meet a wide range of requirements from data centers to industrial and facilities applications.

Download Brochure

  • MGE Galaxy 3500 ((10 – 30 kVA (208V), 10 – 40 kVA (400V)))Performance 3 phase power protection with excellent efficiency and optimized footprint for commercial facilities and industrial environments.

Download Brochure

  • MGE Galaxy 4000 (40 – 75kVA)Flexible 3 phase power protection designed to meet a wide range of requirements from data centers to industrial and facilities applications.

Download Brochure

  • MGE Galaxy PW (150 – 225kVA)Flexible 3 phase power protection designed to meet a wide range of requirements from data centers to industrial and facilities applications.

Download Brochure

Additional UPS solutions from APC:

PTS Uninterruptible Power Supply (UPS) Services

To learn more about PTS consulting services to support Air Conditioning Equipment & Systems deployments and support, contact us or visit:

APC InfraStruxure InRow SC DX Air Cooled High Density Data Center Cooling Solution

btn_contactbtn_video

APC-InRow-SC-DX-Air-Cooled-SolutionInfraStruxure InRow SC DX Air Cooled Data Center Cooling Solutions are modular direct expansion (DX) air conditioning units. They are one-half the width of a standard enclosure, and can be placed in a data-center row. They provide full management capabilities over a network using Telnet, Secure Shell (SSH), HTTP, HTTPS, FTP, Secure Copy (SCP), Modbus and SNMP. The InRow SC provides the following features:

  • Active response controls: Monitors and actively adjusts cooling capacity to ensure proper server inlet temperatures. Through the microprocessor controller, visibility into the operation and health of the unit is provided.
  • Easy to install: Innovative design allows for fast, easy installation by almost anybody.
  • Fault-tolerant fan system: In the event of a fan failure, the remaining fan(s) will continue to operate.
  • Horizontal airflow pattern: Removes heat close to the source of generation in the hot aisle and distributes cold air to the front of the racks in the cold aisle.
  • Scalable Architecture: Cascade multiple KVM switches for a modular solution that supports multiple platforms, improving flexibility and simplifying future expansion. Please see the user’s manual for specific cascading capabilities.
  • Dry contact output: Provides remote notification of failures when used with APC environmental monitoring unit or system.
  • Field replaceable components: Fans and electronics module can be readily replaced without uninstalling the unit.

Features & Benefits

FEATURES BENEFITS

Availability

Predictable cooling Placing the unit in the row of racks moves the source of cooling closer to the heat load. This eliminates air mixing and provides a predictable cooling architecture.
Rack Inlet Temperature Control Reduces the risk of hot spots at the rack level.
Active response controls Monitors and actively adjusts cooling capacity to ensure proper server inlet temperatures. Through the microprocessor controller, visibility into the operation and health of the unit is provided.

Total Cost of Ownership

Variable speed fans Variable speed fans reduce energy consumption during off-peak cooling periods.
In-Row architecture Captures hot exhaust air directly from the IT equipment, thereby increasing the unit’s sensible cooling capacity over traditional cooling architectures.

Agility

Modular design Modular design provides scalable solutions to add cooling as demand increases.
Scalable densities Allows for higher cooling to be achieved by integrating the Hot Aisle Containment System with row-based architecture.

Serviceability

Easy service access Allows for all serviceable components to be replaced / maintained by easily accessible panels/doors.

Manageability

Microprocessor controller Utilizes intelligent, active response control, and real-time monitoring. The system is controlled by a microprocessor providing high level control functionality and human interface via a four line, eighty character, alphanumeric display.
Building Management System Integration Send alarms and data points allowing you to manage critical building infrastructure from a single system.
Real-Time Capacity Monitoring Real-time display of current and available cooling.

APC InfraStruxure InRow RP DX Air Cooled High Density Data Center Cooling Solution

btn_contact

APC-InRow-RP-DX-Air-Cooled-SolutionInfraStruxure InRow RP DX Air Cooled Data Center Cooling Solutions provide high capacity precision air conditioning to maximize cooling for high efficiency operation. Placing the unit in the row of racks moves the source of cooling closer to the heat load. This eliminates air mixing and provides a predictable cooling architecture. The in-row concept closely couples cooling with the heat load, preventing exhaust air recirculation to sensitive IT equipment. An energy-efficient design lowers total cost of ownership by monitoring IT equipment inlet temperatures and modulating capacity based on the demand for cooling. Fan speed is controlled based on the demand to reduce energy consumption during off-peak cooling periods. The modular and scalable solution improves agility by enabling data center operations the ability to add cooling as demand increases, making the InRow RP ideal for small to large data centers.

  • Electric Reheat: Prevents overcooling during dehumidification.
  • Humidifier: Humidity is managed through a self-contained steam canister humidifier for maximum efficiency and ease of maintenance. The pure steam canister maintains consistent capacity output, and requires very little or no scheduled maintenance.
  • Containment system compatible: The unit can be combined with a Rack or Hot Aisle Containment System to eliminate hot air mixing and maximize cooling efficiency.
  • Room Air Distribution: Row-based systems are placed in line with rack enclosures. At least one system is used per hot aisle. Air is drawn in through the rear of the system, cooled, and discharged into the cold aisle, thereby neutralizing the sensible heating effects of the data processing equipment.  The unit delivers high volumes of airflow to eliminate hot spots in densely populated environments.
  • Variable speed fans: The unit is equipped with variable speed, electrically commutated, 400-mm (15.8-in) backward incline, direct drive fans.  The chilled water unit is equipped with three fans while the air-cooled unit has two. In order to provide uniform airflow over the cooling coil, the fans provide a draw-through air pattern. Fans are easily serviced in the field.
  • Microprocessor controller: The microprocessor controller is standard on each system. The controller provides precision control for the demanding requirements of:
    • Computer rooms
    • Telecommunication facilities
    • Clean rooms
    • Power equipment
    • Medical equipment rooms
    • LAN/WAN environments

Features & Benefits

FEATURES BENEFITS
Availability
Predictable cooling Placing the unit in the row of racks moves the source of cooling closer to the heat load. This eliminates air mixing and provides a predictable cooling architecture.
Rack Inlet Temperature Control Reduces the risk of hot spots at the rack level
Active response controls Monitors and actively adjusts cooling capacity to ensure proper server inlet temperatures. Through the microprocessor controller, visibility into the operation and health of the unit is provided.
Total Cost of Ownership
Variable speed fans Variable speed fans reduce energy consumption during off-peak cooling periods.
In-Row architecture Captures hot exhaust air directly from the IT equipment, thereby increasing the unit’s sensible cooling capacity over traditional cooling architectures.
Agility
Modular design Modular design provides scalable solutions to add cooling as demand increases.
Scalable densities Allows for higher cooling to be achieved by integrating the Hot Aisle Containment System with row-based architecture.
Serviceability
Easy service access Allows for all serviceable components to be replaced / maintained by easily accessible panels/doors.
Manageability
Microprocessor controller Utilizes intelligent, active response control, and real-time monitoring. The system is controlled by a microprocessor providing high level control functionality and human interface via a four line, eighty character, alphanumeric display.
Building Management System Integration Send alarms and data points allowing you to manage critical building infrastructure from a single system.
Real-Time Capacity Monitoring Real-time display of current and available cooling.

APC InfraStruxure InRow RD DX Air Cooled High Density Data Center Cooling Solution

btn_contact

APC-InRow-RD-DX-Air-Cooled-SolutionInfraStruxure InRow RD DX Air Cooled Data Center Cooling Solutions are modular direct expansion (DX) air conditioning units.

The row-based solution improves energy efficiency and cooling ability in a number of ways. First, the InRow RD draws air directly from the hot aisle, allowing the InRow RD to take advantage of higher heat transfer efficiency due to higher temperature differences. It can then discharge room-temperature air directly in front of the servers it is cooling. Placing the cooling unit in the row enables the unit to operate at higher return and supply air temperature, yielding 100% sensible capacity. This significantly reduces the need for humidification.

  • Head pressure control: Modulates refrigerant head pressure to protect from coil freeze.
  • Hot swappable fans: Allows system to remain operational if a fan replacement is required.
  • Washable filters: Easy to maintain, cleanable, deep loading mesh filter removes particles from the return air stream.
  • Containment system compatible: The unit can be combined with a Rack or Hot Aisle Containment System to eliminate hot air mixing and maximize cooling efficiency

Features & Benefits

FEATURES BENEFITS
Availability
Predictable cooling Placing the unit in the row of racks moves the source of cooling closer to the heat load. This eliminates air mixing and provides a predictable cooling architecture.
Rack Inlet Temperature Control Reduces the risk of hot spots at the rack level.
Active response controls Monitors and actively adjusts cooling capacity to ensure proper server inlet temperatures. Through the microprocessor controller, visibility into the operation and health of the unit is provided.
Total Cost of Ownership
Variable speed fans Variable speed fans reduce energy consumption during off-peak cooling periods.
In-Row architecture Captures hot exhaust air directly from the IT equipment, thereby increasing the unit’s sensible cooling capacity over traditional cooling architectures.
Agility
Modular design Modular design provides scalable solutions to add cooling as demand increases.
Scalable densities Allows for higher cooling to be achieved by integrating the Hot Aisle Containment System with row-based architecture.
Serviceability
Easy service access Allows for all serviceable components to be replaced / maintained by easily accessible panels/doors.
Manageability
Microprocessor controller Utilizes intelligent, active response control, and real-time monitoring. The system is controlled by a microprocessor providing high level control functionality and human interface via a four line, eighty character, alphanumeric display.
Building Management System Integration Send alarms and data points allowing you to manage critical building infrastructure from a single system.
Real-Time Capacity Monitoring Real-time display of current and available cooling.

APC InfraStruxure InRow RP Chilled Water Data Center Cooling Solution

btn_contact

InfraStruxure InRow RC Chilled Water Data Center Cooling Solutions provide high capacity precision air conditioning to maximize cooling for high efficiency operation. InRow RP is a modular air conditioning unit that is available in either a DX (ACRP100 series) or a chilled water (ACRP500 series) model. It is the width of a standard enclosure, and can be placed in a data-center row. It provides full management capabilities over a network using Telnet, Secure Shell (SSH), HTTP, HTTPS, FTP, Secure Copy (SCP), SMTP, Modbus, and SNMP.

  • Electric Reheat: Prevents overcooling during dehumidification.
  • Humidifier: Humidity is managed through a self-contained steam canister humidifier for maximum efficiency and ease of maintenance. The pure steam canister maintains consistent capacity output, and requires very little or no scheduled maintenance.
FEATURES BENEFITS

Availability

Predictable cooling Placing the unit in the row of racks moves the source of cooling closer to the heat load. This eliminates air mixing and provides a predictable cooling architecture.
Dual A-B Power Inputs Draws power from the UPS for power protection with dual feeds for redundancy.
Rack inlet control Rack inlet control guarantees inlet temperature to IT equipment.
Top and bottom chilled water connections Allows chilled water to be connected from the top, if routing from overhead, or bottom, if on a raised floor.
Active response controls Monitors and actively adjusts cooling capacity to ensure proper server inlet temperatures. Through the microprocessor controller, visibility into the operation and health of the unit is provided.

Total Cost of Ownership

Variable speed fans Variable speed fans reduce energy consumption during off-peak cooling periods.
In-Row architecture Captures hot exhaust air directly from the IT equipment, thereby increasing the unit’s sensible cooling capacity over traditional cooling architectures.

Agility

Modular design Modular design provides scalable solutions to add cooling as demand increases.
Scalable densities Allows for higher cooling to be achieved by integrating the Hot Aisle Containment System with row-based architecture.
Casters Provides flexibility to move the unit to wherever cooling is required.

Serviceability

Easy service access Allows for all serviceable components to be replaced / maintained by easily accessible panels/doors.

Manageability

Microprocessor controller Provides proactive control and real-time monitoring via a four line, eighty character, alphanumeric display.
Building Management System Integration Send alarms and data points allowing you to manage critical building infrastructure from a single system.
Real-Time Capacity Monitoring Real-time display of current and available cooling.

APC InfraStruxure InRow OA Pumped Refrigerant High Density Data Center Cooling Solution

btn_contact

InfraStruxure InRow OA Pumped Refrigerant Data Center Cooling Solutions closely couple the cooling with the IT heat load. This design prevents hot air recirculation, while improving cooling predictability and allowing for a pay as you grow environment. Available in overhead or floor mounted configurations, these products are designed to reduce power and whitespace consumption without introducing chilled water next to IT equipment. Data center operators looking to improve efficiency or deploy high density servers will benefit from the modular design of the InRow Pumped Refrigerant products. The intelligent controls of the InRow Pumped Refrigerant products actively adjust fan speed and refrigerant flow, with no minimum loading, to match the IT heat load to maximize efficiency and address the dynamic demands of today’s IT environments provide high capacity precision air conditioning to maximize cooling for high efficiency operation.

Features & Benefits

FEATURES BENEFITS
Availability
Predictable cooling Placing the unit in the row of racks moves the source of cooling closer to the heat load. This eliminates air mixing and provides a predictable cooling architecture.
Dual A-B Power Inputs Draws power from the UPS for power protection with dual feeds for redundancy.
Rack Inlet Control Rack inlet control guarantees inlet temperature to IT equipment.
Active response controls Monitors and actively adjusts cooling capacity to ensure proper server inlet temperatures. Through the microprocessor controller, visibility into the operation and health of the unit is provided.
No minimum heat load requirement Cooling system will operate from 0 – 100% of the design capacity.
Total Cost of Ownership
Variable speed fans Variable speed fans reduce energy consumption during off-peak cooling periods.
In-Row architecture Captures hot exhaust air directly from the IT equipment, thereby increasing the unit’s sensible cooling capacity over traditional cooling architectures.
Agility
Modular design Modular design provides scalable solutions to add cooling as demand increases.
Scalable densities Allows for higher cooling to be achieved by integrating the Hot Aisle Containment System with row-based architecture.
Serviceability
Easy service access Allows for all serviceable components to be replaced / maintained by easily accessible panels/doors.
Manageability
Real-Time Capacity Monitoring Real-time display of current and available cooling.
Microprocessor controller Provides proactive control and real-time monitoring via a four line, eighty character, alphanumeric display.
Building Management System Integration Send alarms and data points allowing you to manage critical building infrastructure from a single system.

APC InfraStruxure InRow RC Chilled Water Data Center Cooling Solution

btn_contact

APC-InRow-RC-Chilled-Water-Cooling-SolutionInfraStruxure InRow RC Chilled Water Data Center Cooling Solutions provide high capacity precision air conditioning to maximize cooling for high efficiency operation. The solution is an excellent choice for medium to large data centers.

The InRow RC is a chilled water modular air conditioning unit that is available in either a half-rack (ACRC100 series) or a full-rack (ACRC500 series) model. This user’s guide describes the features of the ACRC100-series cooling units. The ACRC100-series models are the widths of a standard enclosure, and can be placed in a data-center row. The InRow RC provides full management capabilities over a network using Telnet, Secure Shell (SSH), HTTP,HTTPS, FTP, Secure Copy (SCP), Modbus, and SNMP.

  • Hot swappable fans: Allows system to remain operational if a fan replacement is required.
  • Washable filters: Easy to maintain, cleanable, deep loading mesh filter removes particles from the return air stream.

Features & Benefits

FEATURES BENEFITS
Availability
Predictable cooling Placing the unit in the row of racks moves the source of cooling closer to the heat load. This eliminates air mixing and provides a predictable cooling architecture.
Dual A-B Power Inputs Draws power from the UPS for power protection with dual feeds for redundancy.
Rack inlet control Rack inlet control guarantees inlet temperature to IT equipment.
Top and bottom chilled water connections Allows chilled water to be connected from the top, if routing from overhead, or bottom, if on a raised floor.
Active response controls Monitors and actively adjusts cooling capacity to ensure proper server inlet temperatures. Through the microprocessor controller, visibility into the operation and health of the unit is provided.
Total Cost of Ownership
Variable speed fans Variable speed fans reduce energy consumption during off-peak cooling periods.
In-Row architecture Captures hot exhaust air directly from the IT equipment, thereby increasing the unit’s sensible cooling capacity over traditional cooling architectures.
Agility
Modular design Modular design provides scalable solutions to add cooling as demand increases.
Scalable densities Allows for higher cooling to be achieved by integrating the Hot Aisle Containment System with row-based architecture.
Casters Provides flexibility to move the unit to wherever cooling is required.
Serviceability
Easy service access Allows for all serviceable components to be replaced / maintained by easily accessible panels/doors.
Manageability
Microprocessor controller Provides proactive control and real-time monitoring via a four line, eighty character, alphanumeric display.
Building Management System Integration Send alarms and data points allowing you to manage critical building infrastructure from a single system.
Real-Time Capacity Monitoring Real-time display of current and available cooling.

To learn more about PTS consulting services to support Air Conditioning Equipment & Systems deployments and support, contact us or visit: